Research at a Glance
Project: Development of a Nondestructive Imaging Tool to Identify Deficiencies in External Tendons Containing Flexible Fillers
Principal Investigator: Christopher L. Alexander, PhD
Sponsor: FDOT
Term: March 2024-July 2026
Technology: Tendon Imaging Unit (TIU)
Deficiencies Detected: Water intrusion and air voids
Key Finding: Technology demonstrated greater sensitivity to water intrusion, a primary corrosion concern.
Implementation Advantage: Minimal variation found among FDOT-approved wax products, simplifying future deployment.
Future Innovation: Rotation-free prototype successfully demonstrated.
A new Florida Department of Transportation (FDOT)-funded study led by Christopher L. Alexander, PhD and researchers at the University of South Florida College of Engineering has demonstrated a promising new approach for identifying hidden defects in wax-filled external post-tensioned bridge tendons without damaging the structure. The project, Development of a Nondestructive Imaging Tool to Identify Deficiencies in External Tendons Containing Flexible Fillers, successfully adapted USF’s Tendon Imaging Unit (TIU) technology to address a longstanding bridge inspection challenge.
Addressing a Critical Infrastructure Challenge
External post-tensioned tendons are critical structural elements used in many segmental and cable-stayed bridges. These steel strands are housed within protective ducts and surrounded by corrosion-protection materials. While previous versions of the TIU were capable of evaluating grout-filled tendons, wax-filled systems presented a unique challenge because wax and air have very similar electrical properties, making hidden defects significantly more difficult to identify.
For transportation agencies, this creates a major asset management concern. Water intrusion and voids can compromise corrosion protection and accelerate deterioration, yet these deficiencies often remain hidden from traditional visual inspection methods.
A Novel Nondestructive Testing Solution
To overcome this challenge, the research team developed a new analysis approach that combines magnetic and impedance measurements to create representative cross-sectional images of a tendon’s internal condition. Rather than relying solely on direct measurements, the system predicts the response of a defect-free tendon and compares it against measured data to identify potential deficiencies.
Laboratory testing demonstrated successful detection and imaging of both water pockets and air voids in wax-filled tendons across multiple strand configurations and fill conditions.
The study also found that the technology is particularly sensitive to water intrusion, a key advantage because water is often the precursor to corrosion-related damage. Researchers reported greater confidence in water detection than air-void detection due to the stronger electrical contrast between wax and water.
In addition, characterization of FDOT-approved wax products revealed minimal variation in electrical properties between manufacturers and little dependence on temperature or measurement frequency under typical inspection conditions. This finding simplifies future implementation because the technology can be applied without requiring separate calibration procedures for different approved waxes.
Transforming Bridge Inspection and Asset Management
For bridge owners and transportation agencies, the ability to detect hidden tendon deficiencies without invasive testing has the potential to improve maintenance planning, reduce inspection costs, and support more informed decisions about repair and rehabilitation priorities.
The software developed through the project provides inspectors with immediate visual indicators of potential issues. Areas suspected of containing water are highlighted in blue, while potential air voids appear in red, creating an intuitive assessment tool for evaluating tendon condition.
Equally important, the research explored a next-generation “rotation-free” TIU prototype. Current tendon imaging methods typically require manual rotation of the inspection device around the tendon. The new prototype incorporates arrays of impedance and magnetic sensors capable of collecting circumferential data without manual rotation. Preliminary testing confirmed the system’s ability to recover strand position information, demonstrating a pathway toward faster inspections and, ultimately, bridge-scale monitoring applications.
Who Benefits?
The research has implications for a broad range of transportation stakeholders, including:
- State departments of transportation responsible for bridge inspection and preservation programs.
- Bridge owners and operators seeking more effective asset management tools.
- Structural engineers and consultants performing condition assessments and rehabilitation planning.
- Researchers advancing nondestructive evaluation technologies.
- The traveling public, which benefits from safer and more reliable infrastructure.
Looking Ahead
The study confirms the feasibility of nondestructive imaging for identifying deficiencies in wax-filled external tendons and establishes a foundation for future field deployment. Researchers recommend continued development of the rotation-free scanning system and creation of standardized analytical libraries that would support implementation across the range of tendon configurations found on Florida bridges.
By successfully adapting the Tendon Imaging Unit for wax-filled tendons, CUTR researchers have advanced a technology that could help agencies detect hidden deterioration earlier, improve inspection efficiency, and support the long-term resilience of critical bridge infrastructure throughout Florida and beyond.
Reference: Christopher L. Alexander, Alberto A. Sagüés, Mahesh Karki, and Laxmi Kandel, Development of a Nondestructive Imaging Tool to Identify Deficiencies in External Tendons Containing Flexible Fillers, FDOT Project BED25-977-20, July 2026.